- 46 -
CAUTION
* Do not start the engine when the machine and the load circuit breaker are ON,
or else, power is supplied to the load at the start of the engine which causes electric
shocks or trouble in the load.
Startup procedure:
(1) check it the emergency stop button is reset.
(2)
Make sure that the circuit breakers of
the machine and the loads are all in the
"OFF" position.
Switch it to the frequency
according to the utility frequency of your
region or country.
(3) Set the frequency chang-eover switch to the
50Hz or 60Hz position.
(4) Set the speed change-over switch to the
"START/IDLING" position.
(5) Turn the single-parallel change-over switch to single side.
(6) Turn the starter switch to "PREHEAT/RUN" position.
(7) After the preheat lamp goes off, turn the starter
switch to "start" position. The engine starts,
release the starter switch and allow to return to the "PREHEAT/RUN"
position.
[Note]
If the engine is warm, the preheat operation is not required.
The duration of preheating differs according to the temperature of cooling water.
And if the temperature of cooling water is high enough, the preheat lamp does not
turn on because no preheating is required.