- 40 -
5-1 Checking prior to operation
         
WARNING
MOVING PARTS can cause severe injury.
Rotary uni
t which runs at a high speed is located
in the machine.
(Note that it is very dangerous if you touch it.)
* Be sure to close the door and lock it during operation.
* When making check or maintenance of the machine,
be sure to stop the machine in advance.
- To prevent unexpected trouble, be sure to check the following points.
(1) Check on engine oil (lubricating oil)
(2) Check on engine cooling water
(3) Checking on fan belt
(4) Checking on fuel
(5) Checking on battery acid
(6) Checking on environmental base drain
(7) Checking on grounding for electric shock protection
(8) Checking for leakage of oil and water
(9) Checking for loose parts
(10) Removal of foreign objects in machine
(11) Checking on blowby drain
Inspection:
(1) Checking on engine oil
(Read the instruction manual for the engine
furnished separately.)
Checking the level of engine oil by the
dipstick. Make sure the oil level is always
between H and L.
When it is below the low limit, supply
oil immediately.
At the same time, check condition of oil
by the dipstick.
[Note]
Oil is consumed gradually during operation. When the machine is to be used
continuously for a long time, be careful with lack of oil.