EasyManua.ls Logo

Denyo DCA-150LSKE - 5-4 Shut Down

Denyo DCA-150LSKE
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 49 -
5-4 Shut down
(1) Turn OFF the circuit breaker of the load. circuit breaker of the load
(2) Turn OFF the circuit breaker of the machine.
circuit breaker of the machine
(3) Set the speed change-over switch in "START/IDLING"
position and put the machine in cooling operation
for about 5 minutes.
cooling operation for about 5 min.
(4) Set the starter switch in "STOP" position.
The engine will stop immediately.
(5) Check the panel light goes off.
(6) Remove the key from the starter
switch and keep it at hand.
stop
(7) Check the amount of fuel. Supply
additional fuel if necessary.
(8) Check for leakage of oil, fuel and water.
[Note]
* The stop button is a push button to stop
the engine in case of an emergency.
When the button is pressed, it must be
emergency stop button
unlocked by turning it clockwise
before the engine can be re-started.
* Check the panel light goes out.