EasyManua.ls Logo

Denyo DCA-150LSKE - Checking;Every 1000 Hours

Denyo DCA-150LSKE
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 74 -
9-7 Checking/every 1000 hours
Checking/every 100, 250 and 500 hours is also required.
(1) Replacement of fuel filter cartridge.
Remove the cartridge type element (cartridge) using
filter wrench.
Clean the filter base. Coat the packing of new
cartridge with engine oil thin. Then, mount the
cartridge.
- When mounting, tighten the cartridge about from
1/2
to 3/4 turn by hand after the packing is
fitted to the seal of the filter base.
After the cartridge is replaced, discharge air
in the fuel piping.
- For details, refer to the instruction manual
for the engine. A nameplate showing the
method of discharging air is also attached
to the machine.
Parts number of fuel filter cartridge :
Model name
Parts number
manufacture
Parts number of manufact
ure
DCA-150LSK
E
Y06020 42585
KOMATSU 600-319-3750
(2) Internal cleaning of an environmental base
Division Procedure
Drain the water or contents collected in an environmental base.
Bolt that unites environmental base with upper base is detached with
the hook of the crane hung on the hanging metal fittings of this machine.
This machine is slowly lifted up, and it separates from an environmental base.
Check and clean the internal environmental base.

Related product manuals