EasyManua.ls Logo

Depaepe Telecom SecurAccess Compact - 12.10. Door latch activation and power schematic

Depaepe Telecom SecurAccess Compact
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SecurAccess Compact – User Guide 36
12.10. Door latch activation and power schematic
The SecurAccess Compact is fitted with a NO/NC driving contact for a remote activation of a door
latch electrical relay.
Following settings can be chosen by local or remote programming:
1. Activation or deactivation of the door latch
2. Activation duration
3. 4 digits access code selection (up to 6 different access codes, Note: 0000 will not work)
4. Fast opening selection
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Door latch activation 6 0 0 : activated (factory setting)
1 : deactivated (Door latch not active)
Activation duration 6 1 Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
1
st
access code 6 2 Enter a 4 digits code, (0000 not allowed)
2
nd
access code 6 3 Enter a 4 digits code, (0000 not allowed)
3
rd
access code 6 4 Enter a 4 digits code, (0000 not allowed)
4
th
access code 6 5 Enter a 4 digits code, (0000 not allowed)
5
th
access code 6 6 Enter a 4 digits code, (0000 not allowed)
6
th
access code 6 7 Enter a 4 digits code, (0000 not allowed)
Fast opening with « 0# » ou « 0* » 6 8 0 = deactivation (factory setting) - 1 = activation
NO: Normally open
NC: Normally close
COM : COMMON
Power
supply
Door latch
NO/NC contact R/T
Up to 60 VA and 2A maximum
Door latch
or
NO
NC
COM

Table of Contents

Related product manuals