SecurAccess Compact – User Guide 36
12.10. Door latch activation and power schematic
The SecurAccess Compact is fitted with a NO/NC driving contact for a remote activation of a door
latch electrical relay.
Following settings can be chosen by local or remote programming:
1. Activation or deactivation of the door latch
2. Activation duration
3. 4 digits access code selection (up to 6 different access codes, Note: 0000 will not work)
4. Fast opening selection
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Door latch activation 6 0 0 : activated (factory setting)
1 : deactivated (Door latch not active)
Activation duration 6 1 Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
1
st
access code 6 2 Enter a 4 digits code, (0000 not allowed)
2
nd
access code 6 3 Enter a 4 digits code, (0000 not allowed)
3
rd
access code 6 4 Enter a 4 digits code, (0000 not allowed)
4
th
access code 6 5 Enter a 4 digits code, (0000 not allowed)
5
th
access code 6 6 Enter a 4 digits code, (0000 not allowed)
6
th
access code 6 7 Enter a 4 digits code, (0000 not allowed)
Fast opening with « 0# » ou « 0* » 6 8 0 = deactivation (factory setting) - 1 = activation
NO: Normally open
NC: Normally close
COM : COMMON
Power
supply
Door latch
NO/NC contact R/T
Up to 60 VA and 2A maximum
Door latch
or
NO
NC
COM