SecurAccess Compact – User Guide 37
12.11. Time out for no answer
Same as for Chain dialling section (§ 12.7).
This setting is used in the chain dialling settings choice and for the automatic hanging up.
If chain dialling is activated, the SecurAccess Compact will automatically dial the following number
stored into the depressed off-hook/memory button after the selected elapsed time before next call.
If chain dialling is deactivated, the unit will automatically hang up.
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Elapsed time before next call 0 8 0 : 10 seconds
1 : 20 seconds
2 : 35 seconds (factory setting)
3 : 1 minute
4 : 5 minutes
*9
12.12. Conversation timer
Talking time can be limited by programming. When this feature is activated and the preset talk time is
elapsed, the SecurAccess Compact will automatically hang up.
Proceed as shown below :
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Talk time duration 0 7 Enter the number of minutes of talk time (from 0 up to 9).
Note : 0 = no limit (factory setting)
*9
12.13. Changing the programming access code
Programming access code coming out from factory setting is : 0000
This code can be modified as indicated below:
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Changing the setting code 9 0 Enter the new 4 digits access code twice
note : 0000 = factory setting
*9
Your new access code :