12.2. Entering remote programming mode
1. Call the SecurAccess Compact and wait until it automatically answers (the number of rings
before automatic answer can be changed, factory setting is 3 rings).
2. Two “beep” tones are emitted and within the following 4 seconds, press * to enter the
programming mode (above 4 seconds, a normal communication is established). Another
double “beep” tones confirm entering the programming mode.
3. Within the following 8 seconds, enter the 4 digits programming access code (0000 with factory
settings):
Ö If a wrong code is entered or if it takes more than 8 seconds to enter the code, 1 “beep”
tone confirms a wrong code was entered: resume the operation.
Ö If the code is correct, 2 “beep” tones will be emitted confirming entering the programming
mode.
Calling the SecurAccess Compact using a Tone dialling telephone.
Dial 0XNNNNNNNN Calling the SecurAccess Compact
2 “beep” tones
The SecurAccess Compact answers and goes off-hook
Enter * Entering the programming mode
2 “beep” tones
Confirming the entry
Enter 0000 4 digits (0000 by default)
2 “beep” tones
Confirming the entry
Note:
All correct entries are confirmed by a double “beep” tone Wrong entries are confirmed by a low long
“beep” tone and the unit will hang up.
12.3. Programming rules
1. Enter the programming mode (local or remote)
2. Choose the setting you wish to modify (See list of settings page XX) and enter its setting
access code.
Setting to modify Setting access code
Settings Code Setting choice
M1 storing for key 1 2 0 Number (22 digits max.) * 9
3. Enter the number to store (memory) or the setting change number.
Number to store or parameter to change
Settings Code Setting choice
M1 storing for key 1 2 0 Number (22 digits max.) * 9
4. Confirm by entering *9
Setting confirmation
Settings Code Setting choice
M1 storing for key 1 2 0 Number (22 digits max.) * 9