EasyManua.ls Logo

Depaepe Telecom SecurAccess Compact - Table for Parameters Settings

Depaepe Telecom SecurAccess Compact
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SecurAccess Compact – User Guide 40
14. Table for parameters settings
Setting to modify Code Setting choice
Factory settings are shown in grey
Conf.
Dialling mode 0 0 Pulse : 0 – Tone : 1 *9
Pulse dialling 0 1 Pulse 66/33 ms : 0 60/40 ms : 1 *9
Ringer level 0 3 Low : 0 - High : 1 *9
Ringer melody 0 4 0 : ringer off
1 : Melody N°1
2 : Melody N°2
3 : Melody N°3
*9
Auto answer 0 5 Enter the number of rings before auto answer (0 up to 9)
Note: 0 = feature deactivated
3 = factory setting
*9
Loudspeaker volume 0 6 Low : 0 – Medium : 1 – High : 2 *9
Talk time duration 0 7 Enter the number of minutes of talk time (from 0 up to 9).
Note : 0 = no limit (factory setting)
*9
Elapsed time before next call 0 8 0 : 10 seconds
1 : 20 seconds
2 : 35 seconds (factory setting)
3 : 1 minute
4 : 5 minutes
*9
Repeated dial 0 9 Enter 0 up to 9 (0 for no repeated dial),
note: factory setting = 0
*9
Number 1 Key n°1 (mandatory) 2 0 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 2 for chain dialling on key n°1 2 1 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 3 for chain dialling on key n°1 2 2 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 4 for chain dialling on key n°1 2 3 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 5 for chain dialling on key n°1 2 4 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 1 Key n°2 (mandatory) 2 5 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 2 for chain dialling on key n°2 2 6 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 3 for chain dialling on key n°2 2 7 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 4 for chain dialling on key n°2 2 8 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Number 5 for chain dialling on key n°2 2 9 Number to store (* # = pause) (22 digits max)
Note : no digit entered erases a previous stored number
*9
Door latch activation 6 0 0 : activated (factory setting)
1 : deactivated (Door latch not active)
*9
Activation duration 6 1 Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
*9
1
st
access code 6 2 Enter a 4 digits code, (0000 not allowed) *9
2
nd
access code 6 3 Enter a 4 digits code, (0000 not allowed) *9
3
rd
access code 6 4 Enter a 4 digits code, (0000 not allowed) *9
4
th
access code 6 5 Enter a 4 digits code, (0000 not allowed) *9
5
th
access code 6 6 Enter a 4 digits code, (0000 not allowed) *9
6
th
access code 6 7 Enter a 4 digits code, (0000 not allowed) *9
Fast opening with « 0# » ou « 0* » 6 8 0 = deactivation (factory setting) - 1 = activation *9
Changing the setting code 9 0 Enter the new 4 digits access code twice
note : 0000 = factory setting
*9
switches back the unit to all factory settings 9 1 Four digits access codes *9
Immediate on Hook 9 9 Close the connection after validation
NB : When storing a number in the memory key , combination of key * # insert a pause (generally used with a PBX).