Configuring network interfaces Configure serial interfaces
Digi TransPort® Routers User Guide
312
Note When the serial port is not in 8-bit parity mode (such as it is in either 8-bit no parity, or 7-
bit with parity), the router will continually check for parity when receiving AT commands and
adjust and match accordingly.
Flow Control
The router supports software flow control using XON/XOFF characters and hardware flow
control using the RS232 RTS and CTS signals. Use this drop-down list to select Software,
Hardware or a combination of Both. To disable flow control, select the None option.
Enable echo on this interface
When enabled, enables command echo when using the command line interpreter. Disable this
setting if the attached terminal provides local echo.
CLI result codes
The required level of verbosity for command result codes. The available options are:
n Verbose
n Numeric
n None
3. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
asy n/a descr Free text-description of
interface
Description
S31=n n/a n/a Where n=
3=115200
4=57600
5=38400
6=19200
7=9600
8=4800
Baud rate
S23=n n/a n/a Where n=
0=None
1=Odd
2=Even
5=8 Data Odd
6=8 Data Even
Default 0
Data Bits / Parity
&Kn n/a n/a Where n =
0=None
1=Hardware
2=Software
3=Both
Flow Control