NCH02 User’s ManualDigital Dream Motion Controller Page -20
4.3.3 Spindle/Output Parameter configuration (Spindle/OUT)
Picture 4-6 Spindle/Output Parameter configuration (Spindle/OUT)
The Picture 4-6 showed above it is the Spindle/Output configuration page.At the chart below we explain
each column setting.By turning the rotary&push button,the user can select and edit the values and confirm.
VSO connects to Speed adjustment which defined by voltage 0-10V.
The relationship Max. Spindle speed and default spindle speed is as below:
VSO(Output Voltage)=10*default spindle speed(S)/Maximum Spindle Speed(Max.S).
For example if we set the Max Speed is 40000,Default speed is 20000,then VSO=10*20000/40000=5V.
Note:The Output Pin No. 0 indicates that the output closed,and the output Pin No. 1-5,the Mark No. is
OUT1-OUT5.
Output Active Electric Level Setting:1=Active,0=Not Active.
1
3
2
No. Mark Definition Range
Max Speed
Default Speed
M3/4 Delay
0-8
1/0
0-8
The max spindle speed
Delay time of M3/4 Directive,Spare enough time for spindle response
The default spindle speed
7
9
11
8
10
12
Spindle CW(M3)
Spindle CCW(M4)
Mist cool(M8)
Flood cool(M10)
0-5
EXT M61
EXT M62
EXT M63
EXT M64
1/0
M3 Pin Number Setting
M4 Pin Number Setting
M8 Pin Number Setting
M10 Pin Number Setting
M60 Pin Number Setting
M61 Pin Number Setting
M62 Pin Number Setting
M63 Pin Number Setting
M64 Pin Number Setting
M3 Active Level
M4 Active Level
M8 Active Level
M10 Active Level
M60 Active Level
M61 Active Level
M62 Active Level
M63 Active Level
M64 Active Level
5
4
6
1/0
1/0
1/0
1/0
1/0
1/0
No. Mark
Pin Selection
Active Level
RangeDefinitionRangeDefinition
1/0
1/0
0-5
0-5
0-5
0-5
0-5
0-5
0-5
0-5
0-5

Related product manuals