Product description
www.dilo-gmbh.com | 0200.bae
Compressor:
The compressor is a dry running type and operates entirely without oil. It is available for different delivery
rates and different final pressures (see technical data).
The compressor housing is absolutely gastight, but the maintenance of the compressor can be carried
out easily. The working overpressure is controlled by a pressure reducer and a contact gauge. The
operating temperature of the motor winding and the cylinder heads are controlled by a thermistor.
(Technical data and description see chapter 11 of the operating manuals for the compressor).
Suction pump:
(if included)
The suction pump allows the recovery of gas down to < pa 1 mbar (absolute). The suction pump is a dry-
running type, which operates entirely without oil. It is protected from inadmissible operating conditions by
a pressure switch, pressure sensor, solenoid valves and regulating valve. The suction pump only
switches on automatically at pressures of about p
e
= 0.1 bar.
The pressure on the output side of the suction pump is controlled by a pressure sensor. The regulating
valve on the suction side prevents a too high output pressure by throttling on the input side.
The output pressure is regulated to about pa 1000- 1050 mbar by the regulating valve on the output of
the suction pump so that the compressor cannot generate any depression on the suction pump and
cause ambient air to be sucked in.
Do not connect any gas compartment with overpressure to the suction side while
the suction pump is running as the suction pump can be damaged by
overpressure.
(Technical data and description see chapter 11 of the operating manuals for the
suction pump).
Vacuum compressor:
(if included)
The vacuum compressor allows the recovery of gas down to < pa 50 mbar.
The vacuum compressor is a dry-running type and is protected from inadmissible operating conditions by
manostat, solenoid valve and return valves.
The vacuum compressor switches on automatically during the gas recovery process.
(Technical data and description see chapter 11 of the operating manuals for the vacuum compressor).
Warning