ACCUMULATOR BATTERY MAINTENANCE
A gel accumulator battery not in service is used on the snowmobile.
12V9Ah (12 volt, 9 ampere-hours) – number 1 in the picture.
If the snowmobile is not used for a long time, take off the accumulator battery to
decrease its discharge. First take off a negative conductor and then a plus wire. While
installing the accumulator battery perform connection recursively. After recharge of
the accumulator battery keep it in a dark ventilated room. If the accumulator battery is
left on the snowmobile, one should disconnect the negative conductor.
Take off the negative conductor on a regular basis and clean a positive and negative
clamps. In case of replacement use a accumulator battery with similar characteristics.
If needed, charge the accumulator battery with the help of a certified charger with a
charge current that makes 0.1 from the battery capacity (900 mА).
CUTOUT
To avoid fire in case of a short circuit in a snowmobile in vehicle network a fuse (2) is used. In case of the fuse breakdown one should
open a plastic box and replace it for a similar one with the same nominal (15A). Installation of fill pieces instead of fuses as well as
installation of fuses more powerful than specified is prohibited!
32