B-40
1-10. Air Supply
Air supply procedures
CAUTION
If you find air filters clogged, immediately replace them (filter elements) with new
ones
If the filters of the air unit clog, it may cause a decrease in air supply to the machine
and resultant machine failure or breakage.
Step No.
Procedure
(Continued from the previous section)
1
Unlock the air valve at the plant facility side.
2
Open the air valve.
3
Locate the air unit at the left of the Z-axis as shown in the figure below to make sure that
the pop-up valve (red) of the unit is not popped up.
If the valve is popped up, it means that the filters inside are clogged. Replace the filter
elements referring to the Maintenance Manual.
Air unit
Check that this red valve is not
popped up.
Continued in the next section.