IC100C Series PRELIMINARY
1592015000 Manual IC100C Series 28/05/03 Page 33 di 38
FA13 CUT-OFF differential in summer 0.0
0
0.0
0
25.0
45
30.0
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA14 Override CUT-OFF in summer 0.0
0
0.0
0
25.0
45
30.0
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA15 Delay time for CUT-OFF 0 250 Sec
FA16 Fan speed in summer night function 30 100 %
FA17 Minimum fan speed in winter 30 100 %
FA18 Maximum fan speed in winter 30 100 %
FA19 Temperature / pressure setpoint for minimum speed in
winter
-40.0
- 40
0.0
0
110
230
30
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA20 Temperature / pressure setpoint for maximum speed in
winter
-40.0
- 40
0.0
0
110
230
30
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA21 Proportional band in winter 0.0
0
0.0
0
25.0
45
30.0
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA22 CUT-OFF differential in winter 0.0
0
0.0
0
25.0
45
30.0
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA23 Override CUT-OFF in winter 0.0
0
0.0
0
25.0
45
30.0
435
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
FA24 Fan speed in winter night function 30 100 %
Hot Start Function
Parameter Description Min Max Meas. Resolution
FA25 Hot Start Setpoint -40
-40
110
230
°C
°F
Decimal
integer
FA26 Hot Start differential 0.0
0
25.0
45
°C
°F
Decimal
integer
Pr2 Password 0 999
Anti-freeze / Heater parameters
Parameter Description Min Max Meas. Resolution
Ar01 Minimum value of Anti-Freeze Setpoint -40.0
-40
Ar03
°C
°F
Decimal
integer
Ar02 Maximum value of Anti-Freeze Setpoint
Ar03
110
230
°C
°F
Decimal
integer
Ar03 Anti-freeze Setpoint Ar01 Ar02 °C/°F Dec/int
Ar04 Anti-Freeze Differential 0
0
25.0
45
°C
°F
Decimal
integer
Ar05 Anti-Freeze alarm delay 0 250 Sec
Ar06 Maximum number of Anti-Freeze alarm events in 1 hour 0 16