Digital Monitoring Products XTLplus Installation and Programming Guide
38
ZONE INFORMATION
Select 2 to send Alarm and Supv/Trbl messages from this zone to receiver 2 only,
regardless of the programming for that receiver.
Select BOTH to send Alarm and Supv/Trbl messages from this zone to both
receivers, regardless of the programming for either receiver.
33.20 Zone Number
Enter the zone number you want to program next. Return to section 32.1 and
follow the descriptions of each programming option. If all zones are programmed,
press the ARROW key at the ZONE NO: – display to continue.
Stop
34.1 Stop
At the STOP option, pressing any select area allows you to exit the programmer
function of the XTLplus panel. When selected, the panel performs an internal reset
and exits the programmer. The Stop function causes the following conditions to
occur:
All 1100 Series DMP Wireless transmitters are reset to NORMALxx
• The panel’s Status List is CLEARED
During the Stop function, all keypad displays are momentarily disabled for two
seconds. Afterwards, the programming function is terminated and the keypads
return to the Status List display.
Set Lockout Code
35.1 Set Lockout Code
Pressing COMMAND at the Stop option displays SET LOCKOUT CODE. This feature
allows you to program a special code that will then be required to gain access to
the panel’s internal Programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1 to 5
digits long (1 to 65535). Do not use leading zeros for the lockout code.
1. Press any select area. The display changes to ENTER CODE: -.
2. Enter a 1- to 5-digit code (do not enter a number higher than 65535). Press
COMMAND.
3. Enter the new Lockout Code again. Press COMMAND. The keypad display changes
to CODE CHANGED.
Once you have changed the code, it is important that you write it down and store
it in a safe place. Lost lockout codes require the panel to be sent back into DMP
for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout
Code command option.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
ZONENO:-
00
STOP
SET LOCKOUT CODE
SETLOCKOUTCODE
STOP