19
Job Screen Display (5 of 6) (F4).
(j) If less than ten jobs are entered in a list, a zero
must be entered in the position following the last
job entered in the list. For example, if Run List A is
to contain eight (8) jobs, a zero must be entered in
the ninth position in the list.
Job details may not be edited from these
screens.
(k) Press F4 and the "RIGHT" arrow key ve (5) times
to access screen 6 of 6.
(l) From this screen the operator can set the Cut Time.
For instructions on setting Cut Time, setting the
Shut-Off Delay and clear the contents of the Job
Library or reset all Dones to zero, see Cut Time
(F7) later in this manual.
Job Screen Display (6 of 6) (F4) or Cut Time (F7).
5. BAND SPEED (F5). (See F4-Screen 4) Pushing
this button displays the band speed. Band speed
may be changed by: (a) Entering a number; (b)
Pushing the "UP" and "DOWN" arrow keys.
Band speeds range is 40 - 360 fpm (12 - 110 m/min).
The machine cannot be programmed for speeds
beyond this range.
6. AUTO (F6). Automatic Cycle On-Off. Pushing
this button initially selects the automatic operating
mode and lights the LED Display window. When
the button is pushed again, the "AUTO" mode is
turned "OFF" and individual "MANUAL" machine
operations such as machine set-up, positioning
material, etc. are activated.
7. CUT TIME (F7). (See F4-Screen 6 of 6) Pushing
this button permits the operator to: (a) Program a
maximum cut time limit; (b) See the elapsed time (in
minutes and seconds) for the cut in progress. (c)
Program Auto System Shut-Off Delay; (d) Clear
all jobs and set Dones to "0".
To set the Cut Time; (a) Press the 0/INS key
and/or the "UP" or "DOWN" arrows key to select
Cut Time Limit. (b) Enter the number of minutes
and/or seconds. (c) Press the "+/-" key to accept
and advance or press the ENTER key twice or the
CLEAR key to quit.
To set the Auto System Shut-off Delay; (a) Press
the 0/INS key and/or the "UP" or "DOWN" arrows
key to select Auto System Shut-off Delay; (b) Enter
the number of minutes desired; (c) Press the "+/-"
key to accept and advance or press the ENTER key
twice or the CLEAR key to quit.