EasyManua.ls Logo

Doosan D55C-5 - Lift Fork Adjustment

Doosan D55C-5
350 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Section
-81-
Problem Probable Cause Corrective Action
Air/Fuel Mixer malfunction Check mixer
z See Engine Service Manual
Air filter clogged Check air filter
z Clean/replace as required
Vacuum leak Check system vacuum hoses from regulator to
FTV and mixer
z Repair/replace as necessary
Pressure regulator malfunction/fuel
pressure too high
Test pressure regulator operation
z See Engine Service Manual
Faulty FTV
(G643E only)
Check FTV for housing cracks or obstructions
z See Advanced Diagnostics FTV operation
z Repair and/or replace as necessary
Weak ignition and/or spark control See Advanced Diagnostics
Incorrect air/fuel control See Advanced Diagnostics
Exhaust system leaks Repair exhaust system
Excessive Fuel
Consumption/LPG
Exhaust Smell
Oxygen sensor failure Replace as necessary
z See Advanced Diagnostics
https://www.forkliftpdfmanuals.com/