DORMA PORTEO
WN 057472 45532 02/08
Adjustments
H
o
l
d
-
o
p
e
n
t
i
m
e
+
+
+
W
a
l
l
b
l
a
n
k
i
n
g
+
+
D
e
l
a
y
e
d
o
p
e
n
i
n
g
+
Adjust hold-open time
"ON"
potentiometer 2
+
Adjust wall blanking (only with optional sensor technology)
"ON"
potentiometer 3
+
Adjustment for application of an electric strike (optional)
DIP switch A
DIP switch A
DIP switch A
1. DIP switch A "ON"
“electric strike”
2. Adjust the delayed opening for the locking mechanism.
potentiometer 4
Adjustment of latching action
DIP switch A in
"ON" position
DIP switch A "OFF"
Set program switch in position .
Adjust the desired hold-open time via .
The hold-open time is adjustable for a period from approx. 5 sec. to 30 sec.
= 5 sec. hold-open time
= 30 sec. hold-open time
Set power switch in position .
Adjust the wall blanking via
The wall blanking is adjustable from approx. 80° to 110°.
= 80° opening angle
= 110° opening angle
Following commissioning, the has a different function.
The electric strike can be activated with following commissioning.
The previous settings/adjustments (arm version) then remain unchanged.
The control unit requires the information that an electric strike is applied.
Therefore, the has to be set to the “correct” position
Set to position.
The function is now activated.
Adjust the delayed opening for the locking mechanism via .
The delayed opening for the locking mechanism is adjustable for a period from
approx. 0.2 sec. to 3 sec.
= 0.2 sec. delayed opening of locking mechanism
+ = 3 sec. delayed opening of locking mechanism
When the electric strike is activated, also the latching action is activated (
).
- in position = the latching action is deactivated.
Adjustment of hold-open time during "PowerLess" operation mode/function.
potentiometer 1 "PowerLess"
potentiometer 2
Turn to position.
Adjust the desired hold-open time via .
The hold-open time is adjustable for a period from approx. 0.5 sec. to 30 sec.
= 0,5 sec. hold-open time
+ = 30 sec. hold-open time
.
.
ON
1234
A BCD
OFF
GB 23