57
ED50/ED100/ED250 09-2021DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Static force in closing direction
ED: Low energy only.
ED/ED: can be configured for full energy using Parameter F.
• Static force in closing direction (basic parameter for wind load control).
• Static force on door closing edge can be changed using this parameter.
• After parameter adjustment, internal monitoring system checks if parameter setting
is admissible. If setting exceeds admissible value, the setting is alternately displayed
with the permissible value.
. After parameter set, verify setting meets ANSI/BHMA standards. See Chapter .
Low Energy
ANSI/BHMA A.
Parameter
setting *
N - N
. lb f - . lb f
6
Full Energy
ANSI/BHMA A.
Parameter
setting *
N - N
. lb f - . lb f
6
Motor driven latching action, automatic
mode
• System offers a motor driven latching action in automatic mode in addition to
mechanical latching action.
• Static force in opening direction (basic parameter for wind load control).
• Low energy operator (ANSI/BHMA A.): static force range is reduced.
• The EP parameter setting is designed to increase static force on door closing edge to
insure proper closing despite resistance caused by door seals or locking devices.
. After EP parameter set, verify setting meets ANSI/BHMA standards. See Chapter .
• After parameter adjustment, internal monitoring system checks if parameter setting
is admissible. If setting exceeds admissible value, the setting is alternately displayed
with the permissible value.
. Setting should be increased step by step from a low setting so as to avoid damage
to the system. Use the lowest possible setting.
. Ensure that both the door itself and the push or pull arm installation are suitable for
the additional, permanent forces.
-
Motor driven latching action angle
Door opening angle at which motor driven latching action EP is activated.
• Starting angle of the latching angle adjustable from °.
- °
Keep closed force
-
Off
to
• Keep closed force can be set from (off) to , maximum force.
• Keep closed force is:
• Permanently applied following motor drive latching action.
• Designed to keep door in closed position even if wind acts on door.
Push & Go
-
Off
• Door close mode parameter hd must be set to "" (automatic) to enable this
function.
. When set to , parameter is activated.
• Automatic opening of door is started when door is manually moved ° out of
the closed position.
A.. Driving parameters detail.