dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Factory setting level
Parameter SL is used to determine what data will be reset during factory setting
process.
Reset Standard factory settings (SL= default)
. Mode switch: CLOSE.
. Door closed.
. Press button keypad down button
for greater than s.
• All parameters reset to factory settings.
• Procedure completed when "" on digit displays blinks twice.
• Installed upgrade cards remain valid and do not require reinstallation.
. Learning cycle required.
Reset Extended factory settings (SL=)
. Mode switch: CLOSE.
. Door closed.
. Set SL to .
. Press button keypad down button for greater than s.
• All parameters reset to factory settings.
• Installed upgrade cards deleted from operator memory.
• Parameter SL automatically reset to .
• Control unit and upgrade cards can be used independently (delivery status).
• Procedure completed when "" on digit displays blinks twice.
. Learning cycle required..
1 - 2
Opening angle
• Door opening angle set during learning cycle is displayed.
• Opening angle can only be changed during learning cycle.
• Due to installation and parameter tolerances, display value may not match actual
door position.
-
°
Door closer mode
-
=Automatic mode. This mode is applicable whenever door is mainly opened
automatically and where motion detectors are installed.
• Mode is optimized for high frequency use.
• Full energy upgrade card provides for higher door opening and closing speeds.
• In case door is blocked during a closing cycle, operator reverses automatically.
• Driving phase is optimized to provide reliable closing cycles.
• Keep closed force (wind load control) parameter FH and Push & Go function
parameter PG are only available in automatic mode.
=Manual mode. This mode is applicable whenever door is mainly used manually
and only rarely automatically.
• In case door is blocked during a closing cycle, door will stop at its current
position.
• Driving phase optimized for manual opening cycles.
• Power assist function parameter hf is only available in manual mode.
Power assist activation angle
• Setting of door activation angle for Power assist function (hF).
• Higher settings of hA result in better spring force compensation for easier manual
opening.
• Power assist function is more sensitive the smaller the activation angle.
- °
A.. Driving parameters detail.