ED50/ED100/ED250 09-2021DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Upgrade card barrier-free toilet
. Once upgrade card installed, parameter value will automatically change to 
(upgrade card installed, function not activated).
. Activate function by changing parameter F to .
. Operator power reset is required; turn power switch off, wait  s and turn power
back on.
Upgrade card assigns inputs and outputs of the control unit with functions which are
required for this application.

Available
upgrade card
codes
(Para. A..)
, ,
, 
Upgrade card DCW
. Activate function by installing upgrade card, parameter value will automatically
change to .
Upgrade card provides operator with DCW bus connection.
Plug for terminal board X socket included with upgrade card.
DCW bus enables connection of:
Program switch EPS DCW (max. )
Motor lock controls SVP-S x DCW (max. )
Motor lock SVP  (max. )
RM-ED lintel mounted smoke detector
Key switch button ST  DCW (max. )
I/O module DCW (max. )

Available
upgrade card
codes
(Para. A..)
, , 
COM  configuration interface

0 - 1
Interface programmed for communication with dormakaba handheld.
Interface programmed for use with dormakaba TMS Soft control software.
Backcheck when door opened manually
Angle after which door is braked when manually opened.
Back check level is automatically optimized during manual door opening cycles.
bc function improves door braking behavior in end position so door does not move
beyond set opening angle OA
. Entered bc value is subtracted from set opening angle OA, example:
Opening angle, °:
Parameter bc, °, door back check starts at °.

 - 
(v.)
° 
Door thickness
. Enter parameter Td in mm.
Door thickness affects measured door opening angle.
Parameter Td enables a more accurate door width to be entered, if required.

 -  mm 
Td
 -
 /"
 /"
Deactivation of drive; X,  and a, trigger
type

0 - 1
NC contact, drive function is deactivated when NC contact is open.
NO contact, drive function is deactivated when NO contact is closed.
Night-bank contact X;  and , trigger
type

0 - 1
. NO contact, night-bank function is triggered when NO contact is closed.
Typically used when using a key switch or an access control system.
. NC contact, night-bank function is triggered when NC contact is opened.
Typically used when connected to building management system to trigger
doors (signal normally present).
A.. Driving parameters detail.