EasyManua.ls Logo

Dover Markem-Imaje LASER 7031 - Page 55

Dover Markem-Imaje LASER 7031
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Printer description
A70622-D1
55/192
Complete connection – Remote Stop/Start and Filter warning:
Note : Cable between the extractor and the laser must be ordered separately (Ref A70148)
Air cooler setting
It is not necessary to set the air flow to the maximum level (two levels are sufficient).
Installation (with IP65 HD head)
The system was qualified with 9 meters hose. A longer hose will affect the performance
(pressure losses).
Air inlet: no tubing, air inlet by the bottom of the pump
Air outlet Diameter 75 mm circular
Outlet tube D = 75 mm L = 7 meters
Exhaust head tube D = 75 mm L = 2 meters
Connections to the head: 75 mm circular
Fittings = 75 mm x 3 units (1 for the pump, 1 for the head inlet, 1 for the head outlet)
Tubing / fittings
Clamps for tubing fixation = 10 units
FS400
Controller I/O Board

Related product manuals