Technical Data
Page 26 of 42
9023810 - 2nd edition - September 2005
Device description acc. to 94/9/EC Typ XTR 0000, XTR 0001, XTR 0010 or XTR 0011
0158
II 2G EEx de IIC T6/T5/T4
II 2D IP 6x T85/T100/T135
o
C
–40
o
C ≤ Ta ≤ +40/+55/+65
o
C
TPS 04 ATEX 1 003 X
NON-INTRINSICALLY SAFE CIRCUITS
INTERNALLY IP30 PROTECTED
Year of manufacturing
1)
1)
The year of manufacturing is coded by the third capital letter of the serial number on the type plate:
U = 2004, W = 2005, X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.
Example: Serial number ARUL-0054, the 3rd capital letter is U, so the year of manufacturing is 2004.
Dräger Safety, D-23560 Lübeck, Germany
Device description acc. to 94/9/EC Typ XTR 0090 or XTR 0091
0158
II 2G EEx de IIC T6
II 2D IP 6x T85
o
C
–40
o
C ≤ Ta ≤ +65
o
C
TPS 04 ATEX 1 003 X
NON-INTRINSICALLY SAFE CIRCUITS
INTERNALLY IP30 PROTECTED
Year of manufacturing
1)
Dräger Safety, D-23560 Lübeck, Germany
Electromagnetic compatibility acc. to 89/336/EWG, acc. to EN 50 270
Typ XTR 0000, XTR 0001, XTR 0090 and
XTR 0091 with sensing head SE Ex PR M:
influence ≤5 % LEL (propane)
Typ XTR 0010, XTR 0011, XTR 0090 and
XTR 0091 with sensing head SE Ex LC M:
influence ≤0,5 % LEL (propane)