LHT65 Temperature & Humidity sensor 36 / 56
AT+DISAT
Quit AT Commands mode
OK
Downlink Command:
No downlink command for this feature.
3.6 Set to sleep mode
Feature: Set device to sleep mode
AT Command: AT+SLEEP
Command Example
Function
Response
AT+SLEEP
Set to sleep mode
Clear all stored sensor data…
OK
Downlink Command:
There is no downlink command to set to Sleep mode. 请确认
3.7 Set system time
Feature: Set system time, unix format. See here for formmat detail.
AT Command:
Command Example
Function
AT+TIMESTAMP=1611104352
OK
Set System time to 2021-01-20 00:59:12
Downlink Command:
0xA86007806000 // Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352
3.8 Set Time Sync Mode
Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq),
LoRaWAN server must support v1.0.3 protocol to reply this command.
SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user
need to set this to 0.
AT Command: