Section 5: Programming
on the system:
l Fire (Fire Key, Fire Zones)
l Panic (Panic Key and Panic Zones)
l Burglary (Delay, Instant, Interior, Stay/Away and 24-hour Burglary Zones)
l Opening/Closing Events
l Zone Auto-Bypass. (Please see 08 Zone Auto-Bypass for details).
l Medical (Medical Key, Medical and Emergency Zones)
l Burglary Verified
l Opening After Alarm
l Emergency Alarm
l Duress Alarm
l Holdup Verified
In the armed state, this output deactivates when the system is disarmed. If an alarm activates this output in the disarmed
state, the output deactivates if a valid access code is entered within the bell timeout or if the system is armed after the bell
timeout has expired.
This output activates for silent and audible alarms or medical conditions only. It will not activate during pre-alert or delays.
Note: The PGM attributes for this option, programmed in section [010], differ from the standard selection of attributes nor-
mally programmed.
Note: When this PGM is configured to provide Opening/Closing status, the PGM must be programmed as a timed output, not
latching.
155 System Trouble
This output can be programmed to activate when any of the following trouble conditions are present:
l Service Required
l Loss of Clock
l DC Trouble
l Bus Voltage
l AC Trouble
l Device Fault
l Device Low Battery
l Device Tamper
l RF Delinquency
l Module Supervisory
l Module Tamper
l Communications
l Not Networked
This output deactivates when all of the selected trouble conditions are cleared.
156 Latched System Event (Strobe)
This output can be used to notify the home owner, before they enter the premises, that an alarm has occurred. This output
can be programmed to activate when any of the following alarms occur on the system:
l Burglary (Delay, Instant, Interior, Stay/Away and 24-Hour Burglary Zones)
l Fire (Fire Key, Fire Zones)
l Panic (Panic Key and Panic Zones)
l Medical (Medical Key, Medical and Emergency Zones)
l Supervisory (Supervisory, Freezer and Water Zones)
l Priority (Gas, Heat, Sprinkler and 24-Hour Latching Zones)
l Holdup (Holdup zones)
l Output follows pulse timer (See "[008] PGM Timer Programming" on page 72).
l Duress
l Emergency
l CO Alarm
l Fire Supervisory
l Fire trouble
This output does not activate during pre-alert or delays.
In the armed state, the output deactivates only once the system is disarmed.
- 75 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals