- 6 -
Contact information
For additional information and support on Alarm.com modules, initial account setup, home automation, and all
other Alarm.com products and services, please visit: www.Alarm.com/dealer or contact Alarm.com technical
support at: 1-866-834-0470.
Features
l 128-bit AES encryption via cellular and Internet.
l Back up or primary cellular alarm communication and Ethernet port.
l Automatically switches to 2G (EDGE/GPRS) if HSPA (3G) service is not available.
l Full event reporting to central station.
l Cellular periodic test transmission.
l Integrated call routing.
l Panel remote uploading/downloading support via cellular or Internet.
l PC-LINK connection.
l Programmable labels.
l SIA and Contact ID (CID) formats supported.
l Signal strength and trouble display LEDs.
l Subscriber Identity Module (SIM) card included with communicator.
l Supervision heartbeats sent via cellular.
l 2-way audio capable when used with audio module HSM2955(R) - Refer to HSM2955(R) manual.
Communicator ratings
Model TL8803GI-EU
Power supply ratings
Input Voltage
11.3V - 12.5V DC
(provided by DSC NEO compatible control panel)
Current consumption
Standby Current (Average Value) 100mA@12V (I)
Alarm (Transmitting) Current (Peak Value) 200mA@12V (I)
Cellular Network HSPA 3G
Operating Frequency Quad Band GSM/GPRS/EDGE + HSPA in 850/900/2100MHz
Environmental specifications
Operating Temperature -10°C to 55°C
Storage Temperature -34°C to 60°C
Humidity 93%RH non-condensing
Mechanical specifications
Dimensions 6" x 8.9" x 1.3"
Weight 365g (I)