[012] Receiver #2 Gateway
Default: 000 000 000 000
This is the IP address of the local gateway the T-Link can use to connect with the second
receiver (WAN network). The IP address of the gateway must also be a valid IP address for the
local subnet.
[013] Receiver #2 T-Link Source Port Number
Default: 3065
[014] Receiver #2 T-Link Destination Port Number
Default: 3061
[015] Receiver #3 IP (Static IP address for the third receiver)
Default: 000 000 000 000
Program the IP address of the third receiver.
[016] Receiver #3 Gateway
Default: 000.000.000.000
This is the IP address of the local gateway the T-Link can use to connect with the third receiver
(WAN network). The IP address of the gateway must also be a valid IP address for the local
subnet.
[017] Receiver #3 T-Link Source Port Number
Default: 3066
[018] Receiver #3 T-Link Destination Port Number
Default: 3061
[019] Console Port Number
Default: 3064
[020] TFTP Port
Default: 69
Port used to do the remote flash upload.
[021] DLS Port Number
Default: 3062
[022] SA Port Number
Default: 3063
[023] T-Link Supervision Enable/Disable
Default: 0
When set to 1, the T-Link is supervised by the central station receiver.
NOTE: For UL/ULC installations, this option must be set to 1.
[024] Receiver Failure Debounce Time
The amount of time that must elapse with no heartbeat response from the receiver before the T-
Link TL2XX will generate a Receiver#1 absent condition.
NOTE: For UL installations, this option shall be set to B4h (180s). For ULC installations this
option shall be set to 5Ah (90s) for Security Level 4, and to 4Bh (75s) for Security Level 5.
[025] Receiver Restoral Debounce Time
The amount of time that must elapse when the heartbeat resumes from the receiver before the
T-Link TL2XX will generate a Receiver #1 restoral condition.
[026]-[027] E-mail Address 1 and 2 (64 characters max.)
Default: None

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC T-LINK TL250 and is the answer not in the manual?

DSC T-LINK TL250 Specifications

General IconGeneral
BrandDSC
ModelT-LINK TL250
CategoryCell Phone
LanguageEnglish

Related product manuals