Specifications
7
3 SPECIFICATIONS
3.1 PART NUMBERING
0892 - 001 - 01
3.2 POWER SUPPLY
Minimum supply voltage 8V continuous, 4V for up to 5 minutes.
Cranking dropouts Able to survive 0V for 100mS providing the supply was at least 8V
before the dropout and recovers to 8 volts afterwards.
Maximum supply voltage 32V continuous (transient protection to 64V)
Power up current 3A transient inrush at initial power up.
Typical Operating current 630 mA @ 12 V DC, 315 mA @ 24V DC
3.3 CONFIGURABLE I/O
Number 4 configurable general purpose input / outputs
Not currently fitted to the DSE892 – RESERVED for future use.
Rating TBA
3.4 TERMINAL SPECIFICATION
Connection type Screw terminal, rising clamp, no internal spring
Min cable size 0.5mm² (AWG 20)
Max cable size 2.5mm² (AWG 14)
3.5 USB HOST CONNECTOR
This USB type A socket provides support for connection to one DSE controller.
Use USB type A to USB type B cable.
NOTE: DSE stock a USB suitable cable for this purpose. Part number 016-125.
Product type
DSE892 SNMP Gateway
0892
Variant
Standard version
01
Hardware revision
001