11.6 Hydraulic Unit (DHW)
For special areas, where water is harder than 200 ppm or 12

treatment system, compliant with current regulations.
LEGEND
A DHW exchanger screw
B DHW priority sensor
C Boiler/system drain tap
D

E DHW temperature NTC probe
F 
G DHW Cold inlet
H DHW outlet
11.7 Cleaning The Cold Water Filter

assembly (B). To clean:
Drain domestic hot water system. (C - 150 only)

Remove nut on DHW priority sensor unit using 18 mm
wrench. (B)

Soak in white vinegar and water mixture for 20 minutes.
11.8 Final Commissioning
Perform Automatic Calibration function as detailed in
section 9.8.
Allow heating system to heat. Balance the system to

return pipes at the boiler.
Check system for proper volume and pressure. See page 4
for acceptable volume and pressure.


Repressurize the system.
11.9 Final Assembly
Place front jacket in position over boiler. Secure in
position at top using screws previously removed.
If boiler is to be left in service with the User, set controls
and room thermostat.
If boiler is not to be handed over immediately, close boiler

If there is possibility of boiler being left during frost
conditions drain boiler and system. See section
11: Component Replacement Or Periodic Cleaning.
Manufacturer recommends attaching a label to the boiler
drawing attention to the fact that the system has been
drained.
Model DCCF-150
Hydraulic Assembly (Combi-150)
NOTICE

assembly (DHW), use only Molykote 111 as a lubricant,
not oil or grease.
11 - GENERAL MAINTENANCE AND CLEANING
H G