Information and specications outlined in this manual in eect at the
time of printing of this manual. ECR International reserves the right to
discontinue, change specications or system design at any time without
notice and without incurring any obligation, whatsoever.
2.5 Designated Use
DCCF-150 provide both central heating and domestic
hot water.
DCBF-125 central heating only.
Indoor installation.
Closet or alcove installation. Direct Vent Boiler does not

Direct vent boiler.

(LP/propane).
2.6 The unit MUST NOT:
Directly heat potable water. Indirect heating is
acceptable.
Heat water with non-hydronic heating system
chemicals present (example, swimming pool water).
Toxic chemicals, such as those used for boiler
treatment, shall not be introduced into potable water
used for space heating.
Exceed 43 psig (2.96 bar) maximum system pressure,
or drop below minimum system pressure 7.25 psig
(.50 bar)
Exceed 176°F (80°C) system design temperature.
2.7 Operational Features
Modulates to provide CH Turndown 5.5:1, DHW
Turndown 7:1.
Maximum output available for domestic hot water:
DCCF-150 - 136,000 btu/h (40 kW), capable of
providing 3.5 (U.S.) gpm (13.2 liters/min) with a
temperature rise of 70°F/39°C.

Optional Outdoor Temperature Reset.
Heat exchanger over heat protection.
Boiler operating at maximum operating temperature,
providing heat, pressure gauge should not indicate
more than 26.11 psi / 1.80 bar. If reading exceeds this

2 - Introduction
2.1 

UNITED STATES
National Fuel Gas Code, ANSI Z223.1/NFPA 54
.
National Electrical Code, NFPA 70.
2.2 
installation shall conform to Standard for Controls and Safety
Devices for Automatically Fired Boilers, ANSI/ASME CSD-1.

2.3 Requirements for Commonwealth of
Massachusetts:
Boiler installation must conform to Commonwealth of
Massachusetts code 248 CMR which includes but is not limited
to:

2.4 Manufacturer recommends use of Carbon
Monoxide monitor may be requirement of local
jurisdiction.