Maintenance - 1000h
ICC1300-1EN3.pdf2011-10-10
Maintenance - 1000h
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Ensue that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Ensue that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Replacing the hydraulic oil filter
1
1
Fig. Engine compartment
1. Retaining screws
2. Protective cover
1
2
Unscrew the retaining screws (1) on each side of the
roller.
Remove the protective cover (2).
83