8.4 Running-in instructions
8.4.1
General
The following maintenance work must be performed when running
in new machines or overhauled engines.
NOTICE!
Danger of engine damage!
Up to approx. 250 operating hours check the
engine oil level twice every day
.
Depending on the load the engine is subjected to,
the oil consumption will drop to the normal level
after approx. 100 to 250 operating hours.
8.4.2 After 25 operating hours
1.
Change the engine oil
Ä
Chapter 8.8.1 „Changing the engine
oil“ on page 75.
2. Check the idle speed and the max. speed of the engine,
adjust if necessary
Ä
Chapter 8.9.6 „Checking, adjusting the
engine speed“ on page 89.
3. Check engine and machine for leaks.
4. Retighten the fastening screws on air filter
, exhaust and other
attachments.
5. Retighten the bolted connections on the machine.