2 General visual inspection
The daily routine should comprise a visual inspection around the entire paver finisher.
The following items must be checked:
- Are components or controls damaged?
- Are there leaks on the engine, the hydraulics, the gearbox, etc.?
- Are all fastening points (conveyor, auger, screed, etc.) in order?
- Are the warnings affixed to the vehicle complete and legible?
- Are the non-slip surfaces at ladders, steps, etc. in correct condition, not worn
or soiled?
m
Immediately take actions to correct any detected malfunction to avoid damages, dan-
gers or environmental hazards!
3 Check that the bolts and nuts fit firmly
Bolts and nuts must be checked regularly to ensure that they fit firmly; retighten them
if necessary.
A
The spare parts catalogue states the special torques at the corresponding parts.
A
For the necessary standard torques, please refer to the section "Bolts - torques"
4 Inspection by an expert
A
Have finisher, screed and optional gas or electric system checked by a trained spe-
cialist
- when required (according to the operating conditions and the nature of application),
- however, at least once a year, check that they are all in good operational condition.