65
Insert a
n email
address
if
different fr
om the def
ault
one.
Select
one
of
th
e
two
mod
es
of data
s
harin
g.
Select th
e file for
mat to
share.
Select
the
ap
plication
to
us
e
for
sendin
g.
Exampl
e of the e
xported csv
file and impo
rted in an E
xcel fi
le:
E500
Serial num.
1100
Date
22/12/2017
Time
12:00
Fuel
Natural Ga
s
Altitude
0.000000
m
RH air
50
%
O2
15.7
%
CO
23
ppm
CO2
2.9
%
T flue
100.6
°C
T air
27.0
°C
ηs
90.0
%
NO
0.000
mV
CO-
SEN
258.270
mV
O2
1.131.867
mV
I sen
0.000
uA
I sen
0.000
uA
I sen
100.346
uA
T az
22.5
°C
ΔT
73.6
°C
Qs
10.0
%
λ,n
4.01
Exc. air
4.01
ηc
0.0
%
ηt
90.0
%
Qs (P
CS)
10.0
%
Qt (P
CS)
10.0
%
ηs (PCS)
90.0
%
ηc (PCS)
0.0
%
ηt (PC
S)
90.0
%
NO
0
ppm
NOx
0
ppm
CO (0.0%)
0
ppm
NO (0.0%)
0
ppm
NOx (0.0%)
0
ppm
Draft
4.5
Pa
68
70
Table of Contents
Main Page
Default Chapter
3
Table of Contents
3
1 Important Information
6
Information about this Manual
6
Danger Levels and Other Symbols
6
2 Safety
7
Safety Check
7
Intended Purpose
7
Improper Use of the Product
7
Precautions for the Usage of the Li-Ion Battery Package
7
3 Working Principle
8
General Overview of the Analyzer
8
4 Description of the Product
9
Working Principle
9
Measurement Cells
9
Fuel Types
9
Sample Treatment
9
Pressure Sensor, Piezoelectric, Temperature Compensated
9
Suction Pump
9
Draft Measurement with Sensor Automatic Autozero
9
Bluetooth® Connection
10
IR Connection
10
5 Components Description
11
Instrument Interface
11
6 Technical Specifications
13
Measurement and Accuracy Ranges
14
7 Using the Flue Gas Analyzer
15
Preliminary Operations
15
Warning
15
Analyzer Power Supply
15
Internal Battery Charge Level
15
Use with External Power Pack
16
QR Code Generation
16
Connection Diagram
17
8 Flue Gas Analysis
18
Switching on the Instrument and Out-Calibration
18
Preliminary Operations
19
Inserting the Probe Inside the Stack
19
Performing the Combustion Analysis
20
End of the Analysis
21
9 Menu
23
Menu→Measurements
24
Menu→Measurements→Draft
25
Menu→Measurements→Co Air
26
Menu→Measurements→Pressure
27
Menu→Configuration
28
Menu→Configuration→Analysis
29
Menu→Configuration→Analysis→Fuel
30
Menu→Configuration→Analysis→Condensation
31
Menu→Configuration→Analysis→O2 Reference
32
Menu→Configuration→Analysis→Measure Units
33
Menu→Configuration→Analysis→Autozero
34
Menu→Configuration→Analysis→Air Temp
36
Menu→Configuration→Analysis→Nox/No Ratio
37
Menu→Configuration→Instrument
38
Menu→Configuration→Instrument→Display
39
Menu→Configuration→Instrument→On Site Calib
40
Menu→Configuration→Instrument→Clock
46
Menu→Configuration→Instrument→Bluetooth
47
Menu→Configuration→Alarm
48
Menu→Configuration→Print
49
Menu→Configuration→Print→Pairing
50
Menu→Configuration→Language
51
Menu→Configuration→Reset
52
Menu→Diagnostic
53
Menu→Diagnostic→Sensors
54
Menu→Diagnostic→Gas Probe
55
Menu→Diagnostic→Hardware
56
Menu→Info Service
57
10 Sensors
58
Sensors Arrangement
58
Sensor Types and Relevant Positioning
58
Gas Sensor Life
58
Gas Sensors Life Table
58
11 Maintenance
59
Routine Maintenance
59
Preventive Maintenance
59
Replacing the Gas Sensors
60
Replacing the Battery Pack
63
12 Troubleshooting
65
Troubleshooting Guide
65
13 0 Spare Parts and Servicing
67
Spare Parts and Servicing
67
Service Centers
67
Measurement Units Matching → Abbreviations
72
Related product manuals
E Instruments E4500
144 pages
E Instruments E8500
49 pages
E Instruments E4500-N
144 pages
E Instruments E4500-S
144 pages
E Instruments E8500 Plus
49 pages
E Instruments 4400
69 pages
E Instruments 1500
144 pages