Removal and Disassembly
11
Removal and Disassembly
3. Insert three puller screws in the three tapped holes in the
mounting flange of the rear approximately 1/2 to break the
gasket.
4. Attach a chain hoist to the rear plate and move the plate
evenly to the rear and off the front case dowel pins. Mount
the rear plate in a vise in the upright position.