1. Install the tension spring in the bore of the shift bar housing.
2. Install the tension ball over the spring, and use a screwdriver
or equivalent to hold the tension ball down and insert the end
of the shift bar with the three notches into the housing until
the neutral (middle) notch is over the tension spring and
ball.