Event: automatic input lock
Event: automatic input unlock
Limit: N = 2 input changes during Tb time (3rd change activates input lock)
Tb
Tb Tb Tb Tb
Input activation and deactivation
Input activation and deactivation no reaction
Temporary input lock
Events send to server
Event: input active
Event: input not active
- Locally there can be 2 x N 1 input activations. In summary average number of activations during defined period of time will be preserved.
- N and Tb parameters may be set per input
Temporary lock may be deactivated by SMS or GRPS command (RLIMIT command).
8.3.2. Partitions
Partitions are configured using Partitions tab.
Using partitions you may configure which inputs will be monitored depending on
state of one of the inputs (arming). If arming input is not active then all changes of
the state of the input assigned to partition will be ignored. For the active arming
input all changes of the state of the input assigned to partition will be monitored and
processed in a normal way.