Technical service manual ecoGEO
31
Compressor delay
1. Used to adjust the duration of the compressor switched on delay.
Note: The compressor switched on may experience extra delays due to automatic pre-start
checks.
Trial period
2. Used to enable the trial period. If it is enabled, the heat pump is locked after the
established time.
3. Used to adjust the duration of the trial period.
Note: The trial period must be disabled to unlock the heat pump.
Oil return
1. Used to enable compressor oil return protection.
2. Used to adjust oil return control parameters.
Note: This option is only available for ecoGEO HP models. Changing the default factory
settings is not recommended unless supervised by an authorised technical service.
2.13. Probe configuration
XXXXXX
1. Display the type of probe installed in each analogue input and their current value.
2. Used to enter a correction of the probe readings.
Note: There are screens for all temperature and hydraulic pressure probes and for the
external temperature probe.
2.14. Manual activation of components
XXXXXX
1. Used to activate the various components controlled by the heat pump manually, both
internal and external.
2. For components with modulating control, used to adjust different regulation values
manually.
Alarm log
1. Used to delete the alarm history log.