Fault Warning 63.13 - Sensor Fault
Cause Sensor is faulty (short circuit)
Remedy Contact us.
Fault Warning 70.11 - DP E/C Temp High
Cause Pump dry end cover temperature is high
Remedy Check that the cooling water supply is connected and switched on. The supply must
be as per the specicaon given in Cooling water data on page 21.
Fault Warning 70.13 - Sensor missing
Cause The dry pump end cover temperature sensor has possibly become disconnected
or f
ailed
R
emedy Check that the sensor is installed and is correctly connected.
Fault Warning 70.13 - Sensor Fault
Cause Sensor is faulty (short circuit)
Remedy Contact us.
Fault Warning 71.13 - AC Sup Missing
Cause The pump controller cannot communicate with the accessory module
Remedy
1. Check that the accessory module is correctly connected to the pump and
then cycle the power to the pump.
2. If this warning connues, contact us.
Fault Warning 84.11 - Exh Temp High
Cause The exhaust pipe temperature is too high.
Remedy Contact us.
Fault Warning 84.13 - Sensor missing
Cause The exhaust pipe temperature sensor has possibly become disconnected or
failed.
R
emedy Contact us.
Fault Warning 84.13 - Sensor Fault
Cause Sensor is faulty (short circuit)
Remedy Contact us.
10/2020 - ©Edwards Limited
Page 73M56635880_D
M56635880_D - Fault nding

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards iXM Series and is the answer not in the manual?

Edwards iXM Series Specifications

General IconGeneral
BrandEdwards
ModeliXM Series
CategoryWater Pump
LanguageEnglish

Related product manuals