Fault Warning 56.11 - Exh Temp High
Cause Exhaust temperature high.
Remedy Contact us.
Fault Warning 56.13 - Sensor Missing
Cause Sensor is missing (open circuit).
Remedy Check that the sensor is installed and is correctly connected.
Fault Warning 56.13 - Sensor Fault
Cause Sensor is faulty (short circuit).
Remedy Contact supplier.
Fault Warning 57.11 - DP Mtr Temp High
Cause Pump temperature high.
Remedy Check that cooling water is connected, switched on and is to specicaon giv
en in
Cooling water data on page 21.
Fault Warning 57.13 - Sensor missing
Cause The dry pump end cover temperature sensor has possibly become disconnected
or failed.
Remedy Check that the sensor is installed and is correctly connected.
Fault Warning 57.13 - Sensor Fault
Cause Sensor is faulty (short circuit).
Remedy Contact us.
Fault Warning 63.11 - DP Temp High
Cause The internal temperature of the pump is too high.
Remedy Check that cooling water is connected, switched on and is to specicaon giv
en in
Cooling water data on page 21.
Fault Warning 63.13 - Sensor missing
Cause The dry pump temperature sensor has possibly become disconnected or failed
Remedy Contact us.
10/2020 - ©Edwards Limited
Page 72M56635880_D
M56635880_D - Fault nding

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards iXM Series and is the answer not in the manual?

Edwards iXM Series Specifications

General IconGeneral
BrandEdwards
ModeliXM Series
CategoryWater Pump
LanguageEnglish

Related product manuals