5.2 Start the pump
CAUTION: EXCESSIVE ENERGY CONSUMPTION
Risk of damage to equipment. To avoid excessive energy consumpon and damage to
the vacuum pump the maximum allowed starng frequency is 6 starts per hour.
For more frequent operaon, let the pump operate connuously and control the
vacuum demand by a pitot valve on the pump inlet.
To start the pump:
1.
Check oil level and oil condion.
2.
Turn on the power.
5.3 During operaon
Note:
The operator must apply all relevant safety precauons. Refer to Safety precauons
during operaon on page 12 Safety precauons during operaon on page 9 and Fault
nding on page 39 Fault nding on page 43.
Regularly check the oil level and the oil condion. The oil level should be in the middle
of the oil sight glass. Refer to Prevenve maintenance schedule on page 31 Prevenve
maintenance schedule on page 35.
5.4 Stop the pump
We recommend running the unit o-line for typically 30 minutes with closed inlet valve
but open gas ballast prior to switching o. This will condion the oil ready for the next
start‑up. If the gas stream was heavily contaminated with water vapour, a longer period
of running the unit o-line will extend the oil lifeme.
If the pump is stopped before all the condensed vapour has been disposed o, it will be
deposited by gravity separaon from the oil on the boom of the oil aer about 8 to 10
hours.
Before restarng, check for any water in the oil tank-leads to an increase of the oil level
through the oil viewer (high water handling capability versions only). If there is water,
follow the instrucons in Prevenve maintenance schedule on page 31 Prevenve
maintenance schedule on page 35.
In case of long machine downme, refer to Taking out of operaon on page 30 Taking
out of operaon on page 34.
07/2020 - Page 33
A35104880_B - Operaon