8. Fault nding
Table 5
Fault nding
Condions
The pump does not run on page 43
The pump cannot reach stated vacuum on page 43
Pump is noisy on page 43
Pump runs hot on page 44
High oil consumpon on page 44
Pump does not maintain vacuum aer power-o and pump leaks oil on page 44
The expected process vacuum level is not reached on page 45
Fault
The pump does not run
Cause No voltage
Remedy Provide power supply.
Cause Thermal switch has tripped
Remedy Idenfy cause and reset switch.
Cause Room temperature too low
Remedy Restore temperature to allowed value.
Cause Motor damaged
Remedy Contact service department.
Fault The pump cannot reach stated vacuum
Cause Low oil level
Remedy Top up oil.
Cause Oil contaminated
Remedy Replace oil.
Cause Pump gaskets damaged
Remedy Contact service department.
Cause Discharge clogged
Remedy Check couplings and outlet.
Fault
Pump is noisy
Cause Exhaust
lter element clogged
Remedy Replace.
Cause Bearings damaged
07/2020 - Page 43