D395-93-880 Issue A
Page 4 © Edwards Limited 2011. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2Technical data
Note: The operating, storage conditions and performance of the T-Station may depends on the type of backing
pump fitted to the T-Station; refer to the technical data in the appropriate supplementary publications.
2.1 General
2.2 Operating and storage data
2.3 Electrical connections
Dimensions Refer to Figure 2
Electrical data Refer to Table 3 - Electrical data
Degree of protection (to IEC34-5: 1981) IP20
Mass
XDD1 combination
E2M1.5 combination
17 kg max
21 kg max
Ambient operating temperature range 12 °C to 40 °C
Ambient storage temperature range -30 °C to 70 °C
Maximum operating altitude 2000 m max
Equipment type Indoor use only
Pollution degree 2
Maximum ambient operating humidity Max 90% RH non cond at 40 °C
Sound level 56 dB(A)
Maximum outlet pressure
XDD1 pump
E2M1.5 pump
1.1 bar absolute (1.1 x 10
5
Pa)
1.5 bar absolute (1.5 x 10
5
Pa)
Maximum permitted external magnetic field 5 mT (DX turbo)
Electrical supply (refer to Figure 1 item 9)
Inlet plug type
Integral fuse rating
IEC60320
10 A Type T, 20 mm
Backing pump (refer to Figure 1 item 10)
Outlet socket type IEC60320
Turbomolecular pump (refer to Figure 1 item 6)
Connector type
Power supply
Maximum output power
15-way sub-miniature ‘D’ type socket
24 V d.c. nominal
80 W
Active gauge (refer to Figure 1 item 7)
Connector type
Power supply
Maximum power rating
RJ45 8-way
24 V d.c. nominal
4 W