Important safety warnings and precautions for installation and operation.
Detailed technical specifications including environmental and measurement parameters.
Electrical parameters for intrinsic safety in hazardous environments.
Information and visibility requirements for device data plates.
Physical dimensions of the EASZ-2 unit.
Specific dimensions for unit installation based on pipe size.
Overview of the EASZ-2 unit's main components and their functions.
Description of available EASZ-2 models: Standard and Hazardous Area versions.
Explanation of how the EASZ-2 measures water content using dielectric properties.
Role of the inline pre-mixer in ensuring homogeneous fluid for accurate measurement.
Guidelines for optimal unit positioning to ensure accurate readings and environmental considerations.
Requirement for a sampling point before the EASZ-2 for calibration purposes.
Steps and checks for correctly mounting the EASZ-2 unit on site.
Instructions for safe and compliant electrical connection and setup.
Diagram and settings for connecting power supply for standalone operation.
Wiring for open collector output to drive external devices or alarms.
Connection details for active 4-20 mA current loop output.
Connection details for passive 4-20 mA current loop output.
Wiring for RS485 Modbus communication interface.
How to set up a termination resistor for the RS485 bus.
Procedure for configuring the Modbus address using DIP switches.
Information displayed upon powering up the EASZ-2 unit.
How the EASZ-2 displays water content and oil temperature in measuring mode.
Configuration and behavior of low/high alarms and backlight indicators.
Explanation of failure messages and their corresponding causes.
Step-by-step instructions for installing the EASZ-2 configuration software.
How to connect the computer to the EASZ-2 using USB-RS or USB-CL cables.
Overview of the EASZ-2 software interface, including Measuring, Calibration, and Settings tabs.
Details on the memory ranges for input and holding registers used by the EASZ-2.
Explanation of factory calibration and the need for site-specific calibration.
Description of High-Point and Two-Point calibration methods for on-site adjustments.
Information on sending units to EESIFLO for laboratory calibration.
Detailed steps for performing a High-Point only calibration on the EASZ-2.
Step-by-step guide for performing a Two-Point calibration for higher accuracy.
Recommendations for visual and internal inspection of the EASZ-2 unit.
Specific checks during visual inspection for damage, leaks, and seal condition.
Steps for internal inspection, cover removal, and seal checks, especially for Ex versions.
Proper methods for cleaning the EASZ-2 unit without damaging it.
Description of the USB-RS cable for RS485 configuration and connection.
Description of the USB-CL cable for 4-20 mA Current Loop configuration.
Purpose of the RS Connection Box for easier RS485 unit configuration.
Details on EESIFLO's warranty coverage and actions that may invalidate it.
Information about the Declaration of Conformity documents provided with the unit.
Guidelines for conserving the unit for long-term storage to maintain warranty.
Explanation of WEEE directive and proper disposal/recycling of the unit.