EASZ-2 Water In Oil Monitor
Installation and Operating Manual
For variants:
EASZ 2Sd-L Standard
EASZ 2Ex-L For Hazardous Areas
Question and Answer IconNeed help?

Do you have a question about the EESiFlo EASZ 2Sd-L and is the answer not in the manual?

Summary

Introduction to EASZ-2 and Safety

General Safety Warnings

Important safety warnings and precautions for installation and operation.

Technical Specification Details

Specification Parameters

Detailed technical specifications including environmental and measurement parameters.

Intrinsically Safe and Data Plate Information

Intrinsically Safe Parameters

Electrical parameters for intrinsic safety in hazardous environments.

Data Plates Requirements

Information and visibility requirements for device data plates.

Unit and Installation Dimensions

Unit Dimensions

Physical dimensions of the EASZ-2 unit.

Installation Dimensions

Specific dimensions for unit installation based on pipe size.

How the EASZ-2 Works

Unit Description

Overview of the EASZ-2 unit's main components and their functions.

EASZ-2 Variants

Description of available EASZ-2 models: Standard and Hazardous Area versions.

Functionality Explanation

Explanation of how the EASZ-2 measures water content using dielectric properties.

Inline Mixing System

Role of the inline pre-mixer in ensuring homogeneous fluid for accurate measurement.

Installation Procedures

Position Requirements

Guidelines for optimal unit positioning to ensure accurate readings and environmental considerations.

Sampling Point Setup

Requirement for a sampling point before the EASZ-2 for calibration purposes.

Mounting Guidelines

Steps and checks for correctly mounting the EASZ-2 unit on site.

Electrical Connection and Configuration

Instructions for safe and compliant electrical connection and setup.

Cable Paths Management

Pre-Wired Options Overview

Power Supply Requirements

Detailed Connection Diagrams

Power Supply Only Configuration

Diagram and settings for connecting power supply for standalone operation.

Open Collector Output Connection

Wiring for open collector output to drive external devices or alarms.

Current Loop - Active (4 - 20 mA)

Connection details for active 4-20 mA current loop output.

Current Loop - Passive (4 - 20 mA)

Connection details for passive 4-20 mA current loop output.

RS485 (Modbus) Interface Connection

Wiring for RS485 Modbus communication interface.

RS485 Modbus Termination Setup

How to set up a termination resistor for the RS485 bus.

Setting the Modbus Address

Procedure for configuring the Modbus address using DIP switches.

MODBUS Registers Reference

Intrinsic Safety Principles for EASZ-2 Ex

Operation Overview and Indicators

Unit Start Up Sequence

Information displayed upon powering up the EASZ-2 unit.

Measuring Mode Display

How the EASZ-2 displays water content and oil temperature in measuring mode.

Alarms and Backlight Functionality

Configuration and behavior of low/high alarms and backlight indicators.

Failure Message Interpretation

Explanation of failure messages and their corresponding causes.

Software Configuration and Calibration

Software Installation Guide

Step-by-step instructions for installing the EASZ-2 configuration software.

Software Connection Methods

How to connect the computer to the EASZ-2 using USB-RS or USB-CL cables.

Software Description and Tabs

Overview of the EASZ-2 software interface, including Measuring, Calibration, and Settings tabs.

Communication Protocols Used

Details on the memory ranges for input and holding registers used by the EASZ-2.

Calibration Procedures

Factory Default Calibration

Explanation of factory calibration and the need for site-specific calibration.

On-site Calibration Options

Description of High-Point and Two-Point calibration methods for on-site adjustments.

Lab Calibration Service

Information on sending units to EESIFLO for laboratory calibration.

High-Point Calibration Procedure

Detailed steps for performing a High-Point only calibration on the EASZ-2.

Two-Point Calibration Procedure

Step-by-step guide for performing a Two-Point calibration for higher accuracy.

Maintenance, Servicing, and Spare Parts

Maintenance Guidelines

Recommendations for visual and internal inspection of the EASZ-2 unit.

Visual Inspection Checks

Specific checks during visual inspection for damage, leaks, and seal condition.

Internal Inspection Procedures

Steps for internal inspection, cover removal, and seal checks, especially for Ex versions.

Cleaning Instructions

Proper methods for cleaning the EASZ-2 unit without damaging it.

Troubleshooting Common Issues

Available Accessories

USB-RS Com Cable

Description of the USB-RS cable for RS485 configuration and connection.

USB-CL Com Cable

Description of the USB-CL cable for 4-20 mA Current Loop configuration.

RS Connection Box

Purpose of the RS Connection Box for easier RS485 unit configuration.

Spare Parts Identification

Warranty and Compliance Information

Warranty Terms and Conditions

Details on EESIFLO's warranty coverage and actions that may invalidate it.

Declaration of Conformity

Information about the Declaration of Conformity documents provided with the unit.

Long-term Storage Recommendations

Guidelines for conserving the unit for long-term storage to maintain warranty.

WEEE Compliance and Recycling

Explanation of WEEE directive and proper disposal/recycling of the unit.

Contact and Support Information