- AB600A5010 Parameter List
Mode 7 (overlock) parameter 232 = 1 (fast scissors) / parameter 018 = 0 (seam end with stop)
FAm
LS
UoS
-Pd
LSS
PLS
USS
Mode 7
Sewing foot lifting at the seam end
Light barrier
Sequence “overlock mode with stop”
Function “pedal in pos. –2” blocked
Start blockage with light barrier uncovered
Chain suction On after light barrier compensating
stitches
Function “fast scissors”
290 = 7
009 = 1
018 = 0
019 = 2
132 = 0
192 = 0
232 = 1
Positioning speed
Maximum speed
Speed after light barrier sensing
Trimming speed
Start counting for tape cutter 1
End counting for tape cutter 2
Light barrier compensating stitches
ON period of tape cutter 1 (M1)
ON period of tape cutter 2 (M2)
Switch-on delay of sewing foot lifting
≤n2*) When the light barrier compensating stitch count at speed n5 ends, the final count for the cutter (c4) is
controlled by the pedal.
If the stitch count for the cutter is set to 0 and the light barrier compensating stitch count is set to when
the cutting begins, the count is carried out at speed n5 independently of the pedal.