Technical Manual V6.00 46 01.05.2017
Short circuit AUX1 output
Check output with diagnostic
Check cable from output to control board
Short circuit brewing heater
Check heater with diagnostic
Check cable from heater to control board
Short circuit temperature sensor coffee boiler
Check temperature sensor with diagnostic
Check cable from sensor to control board
Temperature sensor coffee boiler interrupted
Check temperature sensor with diagnostic
Check cable from sensor to control board
Short circuit pressure sensor of steam boiler
Check pressure sensor with diagnostic and compare with manometer
Check cable from sensor to control board
iSteam sensor interrupted
Check iSteam sensor with diagnostic
Check cable from sensor to control board
Short circuit iSteam sensor
Check iSteam sensor with diagnostic
Check cable from sensor to control board
Timeout steam boiler filling (120 seconds)
Check filling valve boiler with diagnostic
Check if the water is connected and the tap is open
Check pump
Check non return valve
Check level sensor
Timeout coffee boiler filling (80 seconds)
Check if the water is connected and the tap is open
Install the machine according the installation manual!
Check pump pressure (< 10 bar in Diagnostic)
Check pressure relief valve 11bar
Check non return valve boiler inlet
Brewing valve does not close
Check Flowmeter
Timeout steam boiler pressure (600 seconds)
Check heater steam boiler with diagnostic
Check power supply
Check temperature switch F11 A + B
Check pressure sensor
Timeout coffee boiler temperature (180 seconds)
Check heater coffee boiler with diagnostic
Check power supply
Check temperature switch F10 A + B
Check temperature sensor
Incompatibility between parameters and the SW- version
Switch off and on again – Repeat the SW update
Use the latest version of the software from our download area
Check the clock on the menu or on the control board
Check clock – adjust clock – check clock after some minutes
When repeating the error message remove jumper J10 for 10
min and place it again. Adjust clock.
Incompatibility between the messages and the SW
Check SW and message version
Interruption between control board and powder module
Check if powder module is switched on
Check cable from powder module to control board of the coffee
machine
Short circuit +12V powder board
Check board of powder module
Over temperature mixer motor
Check mixer motor with diagnostic
Check cable from motor to control board
Check if something blocks the mixer
Short circuit mixer motor
Check mixer motor with diagnostic
Check cable from motor to control board
Check mixer motor with diagnostic
Check cable from motor to control board
Check if something blocks the mixer
Over temperature left screw drive motor
Check left screw drive with diagnostic
Check cable from motor to control board
Check if something blocks the left screw drive
Short circuit left screw drive motor
Check left screw drive with diagnostic
Check cable from motor to control board