Technical Manual V6.00 34 01.05.2017
Temperature set point of the coffee boiler
Power management of the group heater
Time for the automatic rinse after the last brewed coffee 0=OFF
Increases the amount of coffee powder for the first coffee after 3 min of no coffee
Shows the brewing time after the preparation
Time to grind 10g of coffee with the left grinder
Time to grind 10g of coffee with the right grinder
Test function to grind and adjust the correct amount of ground coffee for the left grinder
Test function to grind and adjust the correct amount of ground coffee with the right grinder
Time of the left grinder – 50% = both grinders ground the same amount
Modes: Off – Manual – Self-regulating – End switch
Defines the reference product for the left grinder, most time «Espresso»
Requested target time for the left reference product
Defines the reference product for the right grinder, most time «Espresso»
Requested target time for the right reference product
If the parameter «SAG» «Module Type» is on manual, the grinder can be
adjusted with this menu.
Type of the milk module – not installed / Coolbox /Fridge
Time for the automatic rinse after the last delivered milk
Purge the milk pump circuit with the fridge 0=OFF
Renew hourly the milk in the milk tubes when having a cool box
Delay of steam for the milk delivery after a milk auto-rinse
Increase of the rinsing time in case of longer tubes (under counter installation)
Increase of the blowout time in case of longer tubes (under counter installation)
Configuring and testing three different milk temperature (Fast speed – low temperature, low speed
– high temperature)
Configuring three different levels of foam texture
Off=no sensor; Switch = capacitive sensor; Level = pressure sensor
Capacity of the milk container
Starts the automatic calibration and sets the values for the
milk level measurement
Value is from the sensor down to the minimum level; will
be set in auto calibration – should not be changed
Factors for the control of the milk pump speed. These
values will be set by the auto calibration and should not be
changed
“Off” blocks all milk product, when milk level is too low;
“ON” blocks only the milk products, which cannot be done anymore
Level of milk in the container, to activate the Low level-information; with 0.0
the function is deactivated
The right sensor has the same submenu as the left sensor. It will not be repeated.
Shut-off temperature of the foamed milk
Emulsion level of the foamed milk
Shut-off temperature of the steamed milk
Emulsion level of the steamed milk
Activates the indication to purge the iSteam after use
Time after the last iSteam use before «Purge iSteam» is displayed
Installation of Powder module