Technical Manual V6.00 55 01.05.2017
8.3. Software
The software of the Egro ONE Multi Drink is based on the software of Egro ONE and only some menus are different. We
publish here only the menus being different; for all other menus, we refer to the menus in Chapter 5.
Product configuration
The parameters in the “Basic” section are valid for all recipes. The adaptation of a value has an influence on all beverages using this
parameter/value.
Basic
Coffee recipes
Extra shot
Type
Define the type of Extra shot - "Xtra" will create a second
shot with defined values; "Double" makes the selected
coffee product a second time.
Left grinder
1. Select cup size S, M, L, XL, Xtra (if configured)
Right grinder
2.Make settings
Both grinders
Grams
Ground coffee dose
Impulses
Number of flow meter impulses (1 imp. = 0.5 cl)
Pre-Infusion
Pre-Infusion in four levels
Pressure
Three levels of tamping pressures
Bypass
Number of flow meter impulses (1 imp. = 0.5 cl)
Volumes
Size
Defines the size for the four available cups. The cups will be filled up to this value
based on the individual recipes
Topping
Volume reduction
Defines the volume reduction in % from the basic
volumes to add toppings by hand
Coffee volume
S, M, L, XL, Xtra
Defines the coffee volume for the available cups and the
Xtrashot.
Milk values
The basic values define the delivery in a certain time. The delivered product must
be measured and the value adjusted.
Hot milk
Volume of milk or milk foam delivered
Warm milk
Tempered milk
Cold milk
Fine milk foam
Medium milk foam
Coarse milk foam
Test milk
Button to start the milk test
Milk correction right
Factor for correcting the amount in the cup, if the used
types of milk have different foaming behavior. The left
milk will be used as reference.
Milk correction both
Factor for correcting the amount in the cup. Should only be
adjusted if the correction of the right milk was adjusted.
Water values
The basic values define the delivery in a certain time. The delivered product must
be measured and the value adjusted.
Cold water
Volume of water delivered and button to start each water
test individually
Test cold water
Warm water
Test warm water
Hot water
Test hot water
Powder values
The basic values define the delivery in a certain time. The delivered product must
be measured and the value adjusted.
Water
Volume of water delivered for powder preparation
Test water
Button to start the water test
Powder left
Volume of powder left with water delivered
Test powder left
Button to start the powder test left
Powder right
Volume of powder right with water delivered

Table of Contents