4. Service
4.1. Service Booklet
The service booklet is in each machine for information of maintenance done. It has space for breakdowns, which should
be noted down by the service technician.
4.1.1. Open machine
Open machine front: Open front cover, remove ground drawer and loosen screw
Remove side panels: Loose screws in the top cover plate. Then pull side panels upwards and remove.
4.2. Preventive Maintenance
Preventive maintenance ensures a continuous quality of products and reduces unscheduled breakdowns. During
preventive maintenance service will be done and necessary spare parts will be exchanged.
The bases for preventing maintenance are kits with all necessary parts. They are available as “Service kit” and
“Extension kit”.
The preventive maintenance is driven by the number of brewing cycles and/or the predefined time. Reaching the
number of cycles or the time, the coffee machine indicates the message "Perform the preventive maintenance".
We recommend adjusting the maximum brewing cycles to 40’000 cycles and the time to 1 year.
The brewing cycles depend on various criteria as regularity of brewing and cleanings, composition of water, cleaning
product, climatic conditions, etc.
In case of unfavorable conditions adjust the number of brewing cycles.
4.2.1. Service interval
Cycles
40'000
80'000
120'000
160'000
200'000
Time
1 Year
2 Years
3 Years
4 Years
5 Years
Service kit
Service kit &
Service kit iSteam
Service kit &
Extension kit
Service kit &
Service kit iSteam
Service kit
4.2.2. Maintenance
Tables with maintenance tasks for each type of machine are available in our download area. They list the tasks and the
parts and are given with the necessary drawings.
4.2.3. Lubricants
The lubricant table informs which lubricant has to be used according the application. The use of not specified lubricants
can shorten the lifetime extremely.
No
Description
Type
ID
Thermal Range
Area of Application
1
High performance lubricant
Berulub
FG-H 2 SL
059246
-45 - +160°C
All connections:
Boiler fittings, tea- and steam wand,
piston motors
Used for connections and mechanical
moving parts
2
High performance lubricant
Berulub
SIHAF 2
059247
-45 -+160°C
For all rubber seals like:
NBR, EPDM, Viton
Not applicable for Silicon O-Ring!
3
Synth. Assembly Grease
Klübersynth
UH1
64-2403
054567
-30 - +140°C
Piston O-Rings
Do not use with EPDM rubbers!