EasyManua.ls Logo

Electia CTC 1132 - False Alarm Management; Remote Commanding

Electia CTC 1132
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CTC-1132 868AM 2007.07.18
33
T u r n O n
T u r n O f F
If the user choose to Turn On the
power switch, then, power switch will
automatically power on and activated.
On the other hand, if the user choose
Turn off, then power switch will be
power off and deactivated.
The user can set any of those eight
power switch freely according to their
own need.
<
<
N
N
O
O
T
T
E
E
>
>
) When the user is turning the power
switch “Home Matic” modules
ON/OFF from CTC-1132 panel, they
should wait for at least 4 seconds
between each operation.
XI. False Alarm Management
CTC-1132 has a regulatory false alarm
management facility built-in:
9 Dual-Ply Entry Wanring
9 Sequential Verification Alarm
Reporting
1. Dual-Ply Entry Warning
z This is to warn the user that an alarm
report to the Emergency Phone Numbers
is about to be made
z When a zone that is not programmed for
delay is violated during the Entry Delay, or
the correct PIN code was not entered
within the programmed Delay period, a 30-
sec internal alarm is given before an alarm
report is made.
z If a valid user PIN code is entered within
the 30 seconds, the alarm will be aborted
and the system returns to normal status.
z If no valid user PIN code is entered, a
burglar alarm will be sent.
2. Sequential Verification Reporting
z A sequential verification alarm report is
generated when a second alarm from a
different Burglar Door Contact or Burglar
PIR is registered within a 30-min period.
z This Sequential Verification Report will be
sent in addition to the alarm report.
z Alarms cannot be verified after the Entry
Delay has been initiated.
XII. Faulty Situations
z The Control Panel is capable of detecting
following fault events:
9 Control Panel Low Battery
9 AC Power Fail
9 Sensor Out-of-order
9 Sensor Low Battery
9 Device and Control Panel
Tamper
9 Interference Detection
9 GSM isn’t ready
9 GSM PUK
9 GSM PIN Code
z In case any fault condition is detected, the
Control Panel will respond with a “Fault
display and/or “Fault” alarm respectively
according to the nature of the faulty event.
z Device Sabotaged
The Control panel, Door Contact,
Remote Keypad & PIR sensors are
Tamper” protected.
Control Panel
A Tamper switch protects CTC-1132
from any removal attempts away
from its cross mounting bracket
Another Tamper switch protects the
Power Supply Lid from being opened
or removed.
PIR Sensor
z For IR-7 & 8
A Tamper switch protects the
enclosure from being opened.
z For IR-9
A Tamper switch protects the
enclosure from being opened.
A Back-Tamper protects the unit from
being removed from its mounting site
Door Contact
A Tamper switch protects the

Table of Contents